Cleaning A Biological Safety Cabinet

It should be noted that the.
Cleaning a biological safety cabinet. It is also the most common safety cabinet of all the different types available. Over ninety percent of biosafety cabinets worldwide are class ii biosafety cabinets of the type a2 variety. By definition baker model ncb c class ii type b1 cabinet meets the ventilation design characteristics established by the national cancer institute nci for a general purpose clean air biological safety cabinet class ii type b safety cabinet 6 july 1976. Wipe interior of bsc work surface walls interior surface of window and items placed in the cabinet with an efficacious and approved disinfectant.
Class ii type a2 biosafety cabinets. Class ii type a a1 a2 biological safety cabinets the class ii type a biological safety cabinet is the most common class ii cabinet. Enclose any items which have been in contact with the agent and cover any waste containers. 10 easy steps to cleaning a contaminated surface in the biosafety cabinet remember to wear appropriate ppe and leave the biosafety cabinet on during spill cleanup.
It has a common plenum from which 30 of air is exhausted and 70 re circulated to the work area as the downflow. Cleaning a biosafety cabinet or bsc is an important function in terms of both containment and sterility. Allow the cabinet to operate for 5 minutes with no activity which should purge airborne contaminants from the work area. 5 1 3 once in a week remove adhered dust by wet mopping using soap solution.
Ensure the cabinet drain valve is closed prior to starting work to contain spills. Aseptic technique and daily decontamination will eliminate the majority of contaminants. To begin apply disinfect to a towel and decontaminate and remove items from the area of the spill. If the biological safety cabinet is turned off between aseptic processes for routine maintenance or any other reason it should be operated long enough to allow complete purging of room air from the critical area for at least 30 minutes then cleaned and disinfected before use.
5 1 2 dedust the biosafety cabinet daily externally with a clean dry cloth. Afterward wipe the surface with a clean dry cloth to remove the moisture. 10 step decontamination guide for biological safety cabinets from nuaire. 5 1 general cleaning procedure 5 1 1 ensure that the power supply of the biosafety cabinet is switched off.
Put the waste from the spill into a. In addition periodic and thorough decontamination routines including disinfecting all removable parts and surfaces is recommended by the manufacturer and is a good laboratory practice to reduce wear on the equipment and provide greater safety to you your samples and the environment. This is the class ii bsc as specified in the european standard en 12469 and the class ii type a2 bsc as specified in.